Model Number : SXBZ
MOQ : 1
Test Capacity : Up to 5000kVA Dry Type Transformer
Optional Function : Partial Discharge Testing System
Applicable Voltage : 11kV/433V, 33kV/433V
Delivery Time : 5-30 work days
Power Frequency Hipot Unit : 20kVA 100kV AC /140kV DC
Control Mode : Button Control + Computer Data Management
Place of Origin : China
Payment Terms : T/T,L/C
Double Frequency DVDF Source : 50kVA Intermediate Frequency Generator
Packaging Details : plywood case
Main Test Items : Full IEC Standard Transformer Performance Test
Regulator Capacity : 400kVA Continuous Adjustable Output
Certification : CE SGS ISO9001
Brand Name : Sansion
The integrated transformer test bench is a full-set professional testing system independently developed by Sansion Power Electric Co.,Ltd. It complies fully with IEC 60076, IEC 358 and IEC EMC standards, specially designed for 3000kVA & 5000kVA dry-type power transformers with 11kV/433V and 33kV/433V voltage levels.
The whole system integrates measurement unit, control console, power supply unit, high voltage hipot source, intermediate frequency DVDF generator, sampling cabinet and intelligent data management software. It realizes one-stop automatic testing covering all mandatory factory inspection items of power transformers, replacing scattered single testers and greatly improving factory testing efficiency and data accuracy. All test data can be displayed, stored, printed and exported via computer, which meets strict factory quality inspection and third-party calibration requirements.
Independent and freely combinable functional modules, supports split transportation and on-site assembly. No need to purchase multiple separate testers, saves workshop space and equipment investment cost.
Equipped with 0.05-grade sampling CT/PT, power tester with 0.2% basic accuracy, DC resistance tester up to 0.2% precision, ensures reliable test data for transformer factory inspection.
Support manual push-button operation for quick simple tests and automatic computer control for full batch testing. Real-time digital display of three-phase voltage, current, frequency and all test indexes.
Built-in over-current protection for no-load & hipot test, emergency stop mushroom button, sound-light alarm during operation, zero-voltage interlock of regulator to avoid accidental high voltage output.
Software auto converts loss & impedance data to rated temperature; supports A4 laser printing and permanent data storage. All test records can be archived for quality traceability.
All test procedures follow IEC 60076 series international standards, test reports recognized by domestic and overseas power inspection institutions.
400kVA voltage regulator, 400kVA intermediate boosting transformer, 20kVA power frequency hipot transformer and 50kVA intermediate frequency generator meet long-time continuous testing demand.
Key electrical parts adopt Schneider brand, strong anti-interference performance, stable operation under complex workshop environment.
Covers dry-type transformers below 5MVA, 11kV/433V & 33kV/433V, impedance range 5.0%~7.0%, max test current less than 200A.
Partial discharge testing module can be added according to customer factory inspection requirements; OEM/ODM layout and capacity upgrade available.
For full batch factory routine test, type test and semi-finished inspection before delivery.
Used for overhaul performance verification after transformer maintenance.
Professional third-party testing laboratory for transformer performance appraisal.
On-site handover acceptance test for new substation transformers.
Transformer characteristic research and teaching experimental platform.





|
|